Overview: Connection And Wiring Diagrams
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • [email protected]
Step 2: Install And Connect The T24-DoorMaster
Install the T24-DoorMaster in a in-wall socket on the wall behind the door station (inside
the building). Besides the in-wall socket, only two holes are required for the entire cabling.
Hole A
Use a long drill bit to drill a hole from the door station downwards at an angle,
through the brickwork to the in-wall socket of the T24-DoorMaster on the interior
wall surface. Insert a 4-wire cable for MxBus and the anti-theft protection (see Section
2.1.4, Recommendation For Cabling).
Hole B
Use a shorter drill bit to drill a hole through the brickwork from the door lock/
door opener to the in-wall socket of the T24-DoorMaster. Feed the connectors for the
door opener, door contact and door lock switch through this hole (see Section 2.5, Installing
The T24-DoorMaster).
Note
Please contact a specialist (e.g. a locksmith) for the installation and selection of
any components that may be required (door opener, magnetic sensors). Door
openers and door contacts are available as accessories from other suppliers (e.g.
www.assaabloy.com).
Door
T24-DoorMaster
Hole B
Hole A
Wall
Indoors